Kabel Nycy. NYCY 1 x (15800) mmNYCY 1 x (15800) mm 2 06/1 kV 2 06/1 kV Cu / PVC / CWS / PVC (Copper Conductor PVC Insulated Copper Wire Screen PVC Sheathed) Standard Specification IEC 605021 Electrical Data Nom Cross Section Area Overall Diamet.
NYCY Power and signalling cable 06/1 kV PVC insulated and sheathed with concentric protective Cu conductor JUS markPP40 Application Standards Distribution and signalling power cable for static outdoor application (with protection against direct Dimensions – Number Of Cores X Conductor Conductor DiameterExternal DiameterInsulation ThicknessN x mm²mmmmmm2 x 15/1515120 130082 x 25/2519133 14082 x 4/424153 1601 Sheath PVC compound DMV5 acc to HRN HD 6031.
NYCY Cable Eland Cables
Kabel NYCY Kabel NYCY yaitu kabel tegangan rendah dengan perisai (low voltage screened) dengan inti tembaga yang dianilkan pemanasan kemudian didinginkan pelanpelan) dengan sistem isolasi PVC Dilapisi pelindung bagian dalam PVC dan dilengkapi dengan screen Copper Wire serta pelindung atau lapisan terluar PVC Tegangan nominal antara 600.
Tim Kabel NYCY
NYCY cables have a UV and waterresistant oversheath Insulated and bedded in PVC this multicore cable has an operating temperature range of 5 o C to +70 o C NYCY is also available in halogenfree compounds where there is a requirement to reduce risk to human life or equipment caused by acid fumes in the event of fire Part NoCoresNominal Crosssectional Area (mm²)TypeA9NYCY0110110RE / 10A9NYCY0116116RE / 16A9NYCY02015215RE / 15A9NYCY02025225RE / 25.
Kabel NYCY Harga Kabel Listrik Sinarmonas
NYCY is a lowvoltage power cable according to VDE 0276603 with copper conductor concentric conductor and PVC sheath It is suitable for installation in inner areas outdoors underground in water and in concrete and can be installed in a fixed arrangement on cable ladders and cable trays NYCY cables are used as distribution cables for supplying lowvoltage systems and also as control P/nrPart NameAvailability080349on request080030in stock080031in stock080032in stock Conductor material copper bareCustoms Tariff Number (code number) 85446010BCPRclassification according to EN 50575 EcaStandard VDE 0276603.
Nycy 2×1 5re 1 5mm Starkstrom Erdkabel Schwarz Meterware Nycy Starkstromkabel Kabel Und Leitung Elektromaterial Elanto24
NYCY PVC power cable, direct burial, with concentric conductor
NYCY 1 x (1.5800) mmNYCY 1 x (1.5800) mm 0.6/1 kV Kabel
NYCY Faber Kabel Shop
Power and control cable for fixed installation in the following applications For indoor and outdoor use Burial without additional suitable underground protection according to VDE standard HD 603/VDE 0276603 Part 3G (point 4) governing PVC cables for direct burial normal minimum installation depth 06 m but at least 08 m under roads.